Server
HPE
Hewlett Packard Enterprise
Version 10
Vendor products2
SNMP polling26
Cpu Monitoring4 actions
Cpu Usage
CPU
Cpu Usage
CPU Member
Cpu Usage Threshold
CPU
Cpu Usage Threshold
CPU Member
Hardware Monitoring6 actions
Status
Fan
State
Power Supply
Temperature
Power Supply
Wattage
Power Supply
Temperature
Temperature
Threshold
Temperature
HP iLO Monitoring12 actionsHP Integrated Lights-Out Monitoring
Cpu Fan
Cpu Fan Status
Thermal
Status
Power Supply
HP ILO Cpu Status
CPU
HP ILO Fan
Fan
Status
Power Supply
RIV Memory Status
RIV (Rebuild/Initialize/Verify) Memory Status
Memory
Status
Automatic Server Recovery
System Fan
System Fan Status
Thermal
Temperature
Temperature Status
Thermal
Temperature
Temperature
Temperature State
Temperature
Temperature Threshold
Temperature
HPE Device System1 actions
Power Status
Power State
HPE Monitoring1 actions
State
Stack
Memory Monitoring2 actions
Memory Usage
Memory
Memory Usage Threshold
Memory
Entities16
Power Supply
HP iLO Fault Tolerant Power Supply
Hardware
Automatic Server Recovery
HP iLO Automatic Server Recovery
Hardware
CPU
System
Fan
Hardware
Memory
HP iLO Memory
System
Power Supply
HP iLO Power Supply
Hardware
Temperature
HP iLO Temperature
Hardware
Thermal
HP iLO Thermal
Hardware
Power State
Power State
CPU
System
Fan
Hardware
Power Supply
Hardware
Stack
System
CPU Member
System
Memory
System
Temperature
Hardware
Statistics charts4
Cpu Usage
Memory Usage
Power Usage
HPE Switch Power Consumption
Temperature
SNMP discovery tables20
SNMP discovery tables (20)
cpqHeAsrStatus
HP / Compaq Automatic Server Recovery feature status
1.3.6.1.4.1.232.6.2.5.1
cpqHeFltTolFanCondition
The condition of the fan.
1.3.6.1.4.1.232.6.2.6.7.1.9
cpqHeFltTolPowerSupplyStatus
HP / Compaq Power Supply Status
1.3.6.1.4.1.232.6.2.9.3.1.5
cpqHeFltTolPwrSupplyStatus
HP / Compaq The status of the fault tolerant power supply
1.3.6.1.4.1.232.6.2.9.2
cpqHeResilientMemOsMemSize
HP / Compaq The size of memory as seen by the Operating System in MB
1.3.6.1.4.1.232.6.2.14.7
cpqHeResilientMemTotalMemSize
HP / Compaq The total size of memory in MB
1.3.6.1.4.1.232.6.2.14.8
cpqHeTemperatureLocale
HP / Compaq The location of the temperature sensor present in the system
1.3.6.1.4.1.232.6.2.6.8.1.3
cpqHeTemperatureThreshold
HP / Compaq The shutdown threshold temperature sensor setting in degrees celsius
1.3.6.1.4.1.232.6.2.6.8.1.5
cpqHeThermal
HP / Compaq Health Thermal
1.3.6.1.4.1.232.6.2.6
cpqSeCpuName
The name of this processor.
1.3.6.1.4.1.232.1.2.2.1.1.3
cpqSeCpuSpeed
This is the internal speed in megahertz of this processor.
1.3.6.1.4.1.232.1.2.2.1.1.4
hpicfFanState
HPE Switch Fan State
1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.4
hpicfPsModel
HPE Switch Power Supply Model
1.3.6.1.4.1.11.2.14.11.5.1.55.1.1.1.9
hpicfPsWattageMax
HPE Switch Power Supply Maximum Wattage
1.3.6.1.4.1.11.2.14.11.5.1.55.1.1.1.7
hpStackMemberOsVersion
HPE Switch Stack Member OS Version
1.3.6.1.4.1.11.2.14.11.5.1.69.1.3.1.19
hpStackMemberSerialNum
HPE Switch Stack Member Serial Number
1.3.6.1.4.1.11.2.14.11.5.1.69.1.3.1.14
hpSwitchCpuStat
HPE Switch CPU Stat
1.3.6.1.4.1.11.2.14.11.5.1.9.6.1
hpSystemAirName
Name of system which temperature sensor is attached
1.3.6.1.4.1.11.2.14.11.1.2.8.1.1.2
hpSystemAirThresholdTemp
Threshold Temperature of the system
1.3.6.1.4.1.11.2.14.11.1.2.8.1.1.7
powerstate
HP Device power-state
1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.65
See the full capability list
The platform is continuously evolving. Browse features, monitoring coverage, or request a conversation.