Facilities
Apc
American Power Conversion
Version 15
Vendor products1
SNMP polling66
Apc Cooling Sensor5 actions
Humidity
Humidity
Pressure
Pressure
Run Hours
Component
State
Component
Temperature
Temperature
Apc Cooling Statues5 actionsApc Cooling Status
Active Flow Control Status
Cooling
Operating Mode
Cooling
Output State
Cooling
Remote On/Standby
Cooling
Standby Input State
Cooling
Apc PDU Monitoring5 actions
Load
Load
Load Status
Load
Bank State
Status
Power Supply1 Status
Power Supply
Power Supply2 Status
Power Supply
Apc Ups Monitoring51 actionsApc Uninterruptible Power Supply Monitoring
Condition
Ups
Condition
Ups
Connection
Battery
Level
Battery
Capacity
Battery
Charger
Battery
Communication
Battery
Battery Current
Battery
Battery Level
Ups
Replacement
Battery
Replacement
Battery
Run Time Remaining
Battery
Run Time Remaining
Battery
Status
Battery
Status
Battery
Battery Temperature
Battery
Battery Temperature
Battery
Temperature
Battery
Battery Voltage
Battery Actual Voltage
Battery
Battery Voltage
Battery
Communication
Ups
Battery Temperature
Ups
Humidity
Sensor
Humidity
Sensor
Input Frequency
Input / Output
Input Line Voltage
Input / Output
Input Phase Current
Input
Input Phase Power
Input
Input Phase Voltage
Input
Internal Temperature
Input / Output
Max Line Voltage
Input Max Line Voltage
Input / Output
Min Line Voltage
Input Min Line Voltage
Input / Output
On Battery
Ups
State
Ups
State
Ups
Output Frequency
Input / Output
Load
Input / Output
Output Phase Current
Output
Output Phase Power
Output
Output Phase Voltage
Output
Output Status
Ups
Output Voltage
Input / Output
Load
Ups
Load
Ups
Status
Probe
Temperature
Probe
Status
Sensor
Communication
Serial Communication Established
Ups
Temperature
Sensor
Temperature
Probe
Temperature
Sensor
Entities17
Humidity
System
Pressure
System
Component
System
Cooling
System
Temperature
System
Battery
Battery
Input
Electrical
Output
Electrical
Ups
Hardware
Probe
Hardware
Load
System
Power Supply
Hardware
Status
Battery
Sensor
Hardware
Battery
Battery
Input / Output
Electrical
Ups
Hardware
Statistics charts17
Humidity
Pressure
Run Hours
Temperature
Battery Percentage
Battery Run Time
Battery Voltage
Battery Voltage and Run Time
Battery Voltage / Current
Current
Humidity
Load
Power
Temperature
Input
Ups Input Voltage and Frequency
Load
Output
Ups Output Voltage and Frequency
Voltage
SNMP discovery tables36
SNMP discovery tables (36)
coolingUnitAboutDescription
A text description of the information presented in coolingUnitAboutValue.
1.3.6.1.4.1.318.1.1.27.1.3.2.1.2
coolingUnitAboutValue
The actual value of the current table entry.
1.3.6.1.4.1.318.1.1.27.1.3.2.1.3
coolingUnitStatusAnalogDescription
Apc Cooling Unit Status Analog Description
1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.2
coolingUnitStatusAnalogScale
The factor by which coolingUnitStatusAnalogValue is expressed.
1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.5
coolingUnitStatusAnalogUnits
The unit of measure by which coolingUnitStatusAnalogValue is expressed.
1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.4
iemStatusProbeName
APC - A descriptive name for the probe set by the user
1.3.6.1.4.1.318.1.1.10.2.3.2.1.2
rPDUIdentName
APC PDU Name
1.3.6.1.4.1.318.1.1.12.1.1
rPDULoadStatusLoadState
APC PDU LoadStatusLoadState
1.3.6.1.4.1.318.1.1.12.2.3.1.1.3
rPDUStatusBankState
Apc PDU StatusBankState
1.3.6.1.4.1.318.1.1.12.5.2.1.3
sysName
1.3.6.1.2.1.1.5
uioSensorStatusCommStatus
APC communications status of the sensor.
1.3.6.1.4.1.318.1.1.25.1.2.1.10
uioSensorStatusHumidity
APC sensor's current humidity reading in percent relative humidity.
1.3.6.1.4.1.318.1.1.25.1.2.1.7
uioSensorStatusSensorName
APC Sensor Name
1.3.6.1.4.1.318.1.1.25.1.2.1.3
uioSensorStatusTemperatureDegC
APC sensor's current temperature reading in degrees Celsius.
1.3.6.1.4.1.318.1.1.25.1.2.1.6
upsAdvBatteryRecommendedReplaceDate
The recommended replacement date for the battery based on the UPS internal battery life algorithm
1.3.6.1.4.1.318.1.1.1.2.2.21
upsAdvBatteryReplaceIndicator
Indicates whether the UPS batteries need replacing.
1.3.6.1.4.1.318.1.1.1.2.2.4
upsAdvIdentDateOfManufacture
The date when the UPS was manufactured
1.3.6.1.4.1.318.1.1.1.1.2.2
upsAdvIdentFirmwareRevision
The firmware revision of the UPS system's microprocessor
1.3.6.1.4.1.318.1.1.1.1.2.1
upsBasicBatteryLastReplaceDate
The date when the UPS system's batteries were last replaced
1.3.6.1.4.1.318.1.1.1.2.1.3
upsBasicIdentFamilyName
The UPS model family name for the product.
1.3.6.1.4.1.318.1.1.1.1.1.3
upsBasicIdentModel
The UPS model name
1.3.6.1.4.1.318.1.1.1.1.1.1
upsBasicIdentName
An 8 byte ID string identifying the UPS
1.3.6.1.4.1.318.1.1.1.1.1.2
upsBasicStateOutputState
An ASCII string containing the 64 flags representing the current state(s) of the UPS.
1.3.6.1.4.1.318.1.1.1.11.1.1
upsBasicSystemInternalTemperature
The actual internal temperature of the UPS system in Celsius.
1.3.6.1.4.1.318.1.1.1.4.1.4
upsHighPrecBatteryTemperature
The current internal UPS temperature expressed in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.1.2.3.2
upsPhaseInputCurrent
Apc Input Phase Current
1.3.6.1.4.1.318.1.1.1.9.2.3.1.6
upsPhaseInputName
APC Input Phase Name
1.3.6.1.4.1.318.1.1.1.9.2.2.1.6
upsPhaseInputPhaseIndex
APC Input Phase Index
1.3.6.1.4.1.318.1.1.1.9.2.3.1.2
upsPhaseInputPhaseTableIndex
APC Input Phase Identifier
1.3.6.1.4.1.318.1.1.1.9.2.3.1.1
upsPhaseInputPower
Apc Input Phase Power
1.3.6.1.4.1.318.1.1.1.9.2.3.1.9
upsPhaseInputVoltage
Apc Input Phase Voltage
1.3.6.1.4.1.318.1.1.1.9.2.3.1.3
upsPhaseOutputCurrent
Apc Output Phase Current
1.3.6.1.4.1.318.1.1.1.9.3.3.1.4
upsPhaseOutputPhaseIndex
APC Output Phase Index
1.3.6.1.4.1.318.1.1.1.9.3.3.1.2
upsPhaseOutputPhaseTableIndex
APC Output Phase Identifier
1.3.6.1.4.1.318.1.1.1.9.3.3.1.1
upsPhaseOutputPower
Apc Output Phase Power
1.3.6.1.4.1.318.1.1.1.9.3.3.1.13
upsPhaseOutputVoltage
Apc Output Phase Voltage
1.3.6.1.4.1.318.1.1.1.9.3.3.1.3
See the full capability list
The platform is continuously evolving. Browse features, monitoring coverage, or request a conversation.