Server

Dell Idrac

Admin packs are the centralised polling configuration downloaded by each Gemmb platform. They describe how pollers and agents monitor vendors and technologies, and are maintained and continuously updated by Gemmb.

Version 5

All admin packs
Snmp Vendor Products1Snmp Polling Groups1Snmp Entity Definitions9Snmp Discovery Tables11Snmp Polling Actions12Statistics Tables3Chart Data Series3Statistics Charts3

Vendor products1

Dell Idrac

SNMP polling12

Dell Idrac12 actions
  • Battery State

    Battery

  • Fan State

    Fan

  • Memory State

    Memory

  • PeakWatts

    PowerUsage

  • Physical Disk State

    PhysicalDisk

  • Physical Disk Statistics

    PhysicalDisk

  • Power Supply State

    Power

  • PowerUsage State

    PowerUsage

  • Processor State

    CPU

  • Temperatue

    Temperature

  • Temperature State

    Temperature

  • Voltage State

    Voltage

Entities9

  • Battery

    Battery

  • Fan

    Hardware

  • Memory

    System

  • PhysicalDisk

    Hardware

  • Power

    Hardware

  • PowerUsage

    Hardware

  • CPU

    System

  • Temperature

    Hardware

  • Voltage

    Hardware

Statistics charts3

  • Dell Idrac Disk Usage

  • PeakWatts

  • Temperature

SNMP discovery tables11

SNMP discovery tables (11)
  • coolingDeviceFQDD

    "0700.0012.0001.0019 Fully qualified device descriptor (FQDD) of the cooling device."

    1.3.6.1.4.1.674.10892.5.4.700.12.1.19

  • memoryDeviceLocationName

    1100.0050.0001.0008 This attribute defines the location of the memory device.

    1.3.6.1.4.1.674.10892.5.4.1100.50.1.8

  • physicalDiskCapacityInMB

    The size of the physical disk in megabytes

    1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11

  • physicalDiskName

    The physical disk's name as represented in Storage Management.

    1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2

  • powerSupplyFQDD

    "0600.0012.0001.0015 Fully qualified device descriptor (FQDD) of the power supply."

    1.3.6.1.4.1.674.10892.5.4.600.12.1.15

  • powerUsageEntityName

    Dell Idrac power Usage Entity Name

    1.3.6.1.4.1.674.10892.5.4.600.60.1.6

  • processorDeviceStatusLocationName

    "1100.0032.0001.0007 This attribute defines the location name of the processor device status probe."

    1.3.6.1.4.1.674.10892.5.4.1100.32.1.7

  • systemBatteryLocationName

    0600.0050.0001.0007 This attribute defines the location of the battery.

    1.3.6.1.4.1.674.10892.5.4.600.50.1.7

  • systemServiceTag

    This attribute defines the service tag of the system.

    1.3.6.1.4.1.674.10892.5.1.3.2

  • temperatureProbeLocationName

    Dell Idrac temperature Probe Location Name

    1.3.6.1.4.1.674.10892.5.4.700.20.1.8

  • voltageProbeLocationName

    Dell Idrac voltage Probe Location Name

    1.3.6.1.4.1.674.10892.5.4.600.20.1.8

See the full capability list