网络

Ruckus

Ruckus (including Foundry)

版本 6

全部管理包
Snmp Vendor Products2Snmp Trap Profiles34Snmp Polling Groups2Snmp Entity Definitions8Snmp Discovery Tables14Snmp Polling Actions11Statistics Tables4Chart Data Series4Statistics Charts4

厂商产品2

FoundryRuckus

SNMP 轮询11

Foundry Monitoring8 项动作
  • Cpu Usage

    CPU

  • Cpu Usage Threshold

    CPU

  • State

    Fan

  • Memory Usage

    Memory

  • Memory Usage Threshold

    Memory

  • State

    Power Supply

  • State

    Module

  • Temperature

    Temperature

Ruckus Wireless Monitoring3 项动作
  • Status

    Access Point

  • Clients

    Access Point

  • System Node Status

    System Node

实体8

  • CPU

    System

  • Fan

    Hardware

  • Memory

    System

  • Module

    Hardware

  • Power Supply

    Hardware

  • Temperature

    Hardware

  • Access Point

    Wireless

  • System Node

    Wireless

SNMP Trap 配置34

  • Ruckus ruckusSZAPConnectedTrap

    Ruckus SZ. Trigger when there is an AP connected event.

    1.3.6.1.4.1.25053.2.11.1.21

  • Ruckus ruckusSZAPDisconnectedTrap

    Ruckus SZ. Trigger when there is an AP connection lost event.

    1.3.6.1.4.1.25053.2.11.1.23

  • Ruckus ruckusSZAPLostHeartbeatTrap

    Ruckus SZ. Trigger when there is a SZ lost AP heart beat event.

    1.3.6.1.4.1.25053.2.11.1.24

  • Ruckus ruckusSZAPRebootTrap

    Ruckus SZ. Trigger when there is an AP reboot event.

    1.3.6.1.4.1.25053.2.11.1.25

  • Ruckus ruckusSZCPUUsageThresholdExceededTrap

    Ruckus SZ. Trigger when there is a SZ CPU threshold exceeded event.

    1.3.6.1.4.1.25053.2.11.1.6

  • Ruckus ruckusSZDiskUsageThresholdExceededTrap

    Ruckus SZ. Trigger when there is a SZ disk usage threshold exceeded event.

    1.3.6.1.4.1.25053.2.11.1.8

  • Ruckus ruckusSZIpmiFanStatusTrap

    Ruckus SZ. Trigger when there is fan module event.

    1.3.6.1.4.1.25053.2.11.1.261

  • Ruckus ruckusSZIpmiFanTrap

    Ruckus SZ. Trigger when there is system fan event.

    1.3.6.1.4.1.25053.2.11.1.258

  • Ruckus ruckusSZIpmiTempBBTrap

    Ruckus SZ. Trigger when there is baseboard temperature event.

    1.3.6.1.4.1.25053.2.11.1.251

  • Ruckus ruckusSZIpmiTempPTrap

    Ruckus SZ. Trigger when there is processor temperature event.

    1.3.6.1.4.1.25053.2.11.1.256

  • Ruckus ruckusSZLicenseUsageThresholdExceededTrap

    Ruckus SZ. Trigger when there is SZ license usage threshold exceeded event.

    1.3.6.1.4.1.25053.2.11.1.19

  • Ruckus ruckusSZMemoryUsageThresholdExceededTrap

    Ruckus SZ. Trigger when there is a SZ memory threshold exceeded event.

    1.3.6.1.4.1.25053.2.11.1.7

  • Ruckus ruckusSZNodeRestartedTrap

    Ruckus SZ. Trigger when there is a SZ restarted event.

    1.3.6.1.4.1.25053.2.11.1.4

  • Ruckus ruckusSZNodeShutdownTrap

    Ruckus SZ. Trigger when there is a SZ shutdown event.

    1.3.6.1.4.1.25053.2.11.1.5

  • Ruckus ruckusSZSystemMiscEventTrap

    Ruckus SZ. Generic trap triggered by admin specified miscellaneous event.

    1.3.6.1.4.1.25053.2.11.1.1

  • snTrapChasFanFailed

    Foundry / Brocade / Ruckus The SNMP trap that is generated when a fan fails to operate normally.

    1.3.6.1.4.1.1991.0.31

  • snTrapChasFanNormal

    Foundry / Brocade / Ruckus The SNMP trap that is generated when a fan operational status changed from failure to normal.

    1.3.6.1.4.1.1991.0.149

  • snTrapChasFanOK

    Foundry / Brocade / Ruckus The SNMP trap that is generated when a fan operational status changed from failure to normal or change in the fan speed due to temperature variations downwards

    1.3.6.1.4.1.1991.0.1000

  • snTrapChasPwrSupplyFailed

    Foundry / Brocade / Ruckus The SNMP trap that is generated when a power supply operational status changed from normal to failure.

    1.3.6.1.4.1.1991.0.30

  • snTrapChasPwrSupplyOK

    Foundry / Brocade / Ruckus The SNMP trap that is generated when a power supply operational status changed from failure to normal.

    1.3.6.1.4.1.1991.0.81

  • snTrapModuleStatusChange

    Foundry / Brocade / Ruckus The SNMP notification that is generated when a module's operational state changes.

    1.3.6.1.4.1.1991.0.176

  • snTrapOpticalMonitoringAlarm

    Foundry / Brocade / Ruckus The SNMP trap that is generated if there is an alarm during optical monitoring.

    1.3.6.1.4.1.1991.0.1004

  • snTrapOpticalMonitoringError

    Foundry / Brocade / Ruckus The SNMP trap that is generated if there is an error during optical monitoring.

    1.3.6.1.4.1.1991.0.1005

  • snTrapOpticalMonitoringWarning

    Foundry / Brocade / Ruckus The SNMP trap that is generated if there is a warning during optical monitoring.

    1.3.6.1.4.1.1991.0.1003

  • snTrapPsuFanStateChange

    Foundry / Brocade / Ruckus The SNMP trap that is generated when the PSU fan status changed.

    1.3.6.1.4.1.1991.0.214

  • snTrapStackingChasFanFailed

    Foundry / Brocade / Ruckus The SNMP trap that is generated when a fan fails to operate normally for a stacking system.

    1.3.6.1.4.1.1991.0.169

  • snTrapStackingChasFanNormal

    Foundry / Brocade / Ruckus The SNMP trap that is generated when a fan operational status changed from failure to normal for a stacking system

    1.3.6.1.4.1.1991.0.168

  • snTrapStackingChasPwrSupplyFailed

    Foundry / Brocade / Ruckus The SNMP trap that is generated when a power supply operational status changed from normal to failure for a stacking system.

    1.3.6.1.4.1.1991.0.167

  • snTrapStackingChasPwrSupplyOK

    Foundry / Brocade / Ruckus The SNMP trap that is generated when a power supply operational status changed from failure to normal for a stacking system.

    1.3.6.1.4.1.1991.0.166

  • snTrapStackingTemperatureWarning

    Foundry / Brocade / Ruckus The SNMP trap that is generated when the actual temperature reading is above the warning temperature threshold for a stack sytem.

    1.3.6.1.4.1.1991.0.171

  • snTrapSysMemoryLowThreshold

    Foundry / Brocade / Ruckus The SNMP trap that is generated when the available dynamic memory in a card is below 5% of the installed physical memory.

    1.3.6.1.4.1.1991.0.180

  • snTrapSysMemoryOutThreshold

    Foundry / Brocade / Ruckus The SNMP trap that is generated when the dynamic memory fails to be allocated in a system.

    1.3.6.1.4.1.1991.0.181

  • snTrapTemperatureOK

    Foundry / Brocade / Ruckus The SNMP trap that is generated when the actual temperature reading is below the warning temperature threshold.

    1.3.6.1.4.1.1991.0.1001

  • snTrapTemperatureWarning

    Foundry / Brocade / Ruckus The SNMP trap that is generated when the actual temperature reading is above the warning temperature threshold.

    1.3.6.1.4.1.1991.0.36

统计图表4

  • Cpu Usage

  • Memory Usage

  • Temperature

  • Clients

SNMP 发现表14

SNMP 发现表 (14)
  • ruckusCtrlSystemNodeName

    Ruckus ruckusCtrlSystemNodeName

    1.3.6.1.4.1.25053.1.8.1.1.1.1.1.1.2

  • ruckusSZAPDescription

    Ruckus SmartZone. Description of AP

    1.3.6.1.4.1.25053.1.4.2.1.1.2.2.1.22

  • ruckusSZAPFWversion

    Ruckus SmartZone. Current Firmware version of AP

    1.3.6.1.4.1.25053.1.4.2.1.1.2.2.1.7

  • ruckusSZAPIp

    Ruckus SmartZone. IP address assigned to AP

    1.3.6.1.4.1.25053.1.4.2.1.1.2.2.1.10

  • ruckusSZAPLocation

    Ruckus SmartZone. AP location info

    1.3.6.1.4.1.25053.1.4.2.1.1.2.2.1.19

  • ruckusSZAPModel

    Ruckus SmartZone. Model name of AP

    1.3.6.1.4.1.25053.1.4.2.1.1.2.2.1.8

  • ruckusSZAPName

    Ruckus SmartZone. Name of AP

    1.3.6.1.4.1.25053.1.4.2.1.1.2.2.1.5

  • ruckusSZAPSerial

    Ruckus SmartZone. Serial Number of AP

    1.3.6.1.4.1.25053.1.4.2.1.1.2.2.1.9

  • snAgentBrdMainBrdDescription

    Foundry / Brocade / Ruckus The main board description string.

    1.3.6.1.4.1.1991.1.1.2.2.1.1.2

  • snAgentCpuUtilPercent

    Foundry. The statistical CPU utilization in units of a percent.

    1.3.6.1.4.1.1991.1.1.2.11.1.1.5

  • snAgentTempSensorDescr

    Foundry. Describes the temperature sensor in a human readable form.

    1.3.6.1.4.1.1991.1.1.2.13.1.1.3

  • snAgSystemDRAMTotal

    Foundry. The total amount of system dynamic memory, in number of bytes.

    1.3.6.1.4.1.1991.1.1.2.12.4.2

  • snChasFan2Description

    Foundry fan description string.

    1.3.6.1.4.1.1991.1.1.1.3.2.1.3

  • snChasPwrSupply2Description

    Foundry power supply description string.

    1.3.6.1.4.1.1991.1.1.1.2.2.1.3

查看完整能力清单